698 Views
Megacli é o utilitário de linha de comando que provê comunicação com placas controladoras da família LSI. A LSI fornece placas controladoras para hardware Supermicro e Dell, por exemplo.
O problema do MegaCli é que ele não é intuitivo. Isso é um problema, pois a recorrência de falhas de RAID pode ser algo bem baixo, logo, a memorização dos parâmetros se torna bastante difícil. Outro ponto negativo é a saída de tela com erros, pois é feito com códigos, e não mensagens.
A seguir temos a relação de códigos de saída do MegaCli e a respectiva explicação.
0x00: Command completed successfully 0x01: Invalid command 0x02: DCMD opcode is invalid 0x03: Input parameters are invalid 0x04: Invalid sequence number 0x05: Abort isn't possible for the requested command 0x06: Application 'host' code not found 0x07: Application already in use - try later 0x08: Application not initialized 0x09: Given array index is invalid 0x0a: Unable to add missing drive to array, as row has no empty slots 0x0b: Some of the CFG resources conflict with each other or the current config 0x0c: Invalid device ID / select-timeout 0x0d: Drive is too small for requested operation 0x0e: Flash memory allocation failed 0x0f: Flash download already in progress 0x10: Flash operation failed 0x11: Flash image was bad 0x12: Downloaded flash image is incomplete 0x13: Flash OPEN was not done 0x14: Flash sequence is not active 0x15: Flush command failed 0x16: Specified application doesn't have host-resident code 0x17: LD operation not possibe - CC is in progress 0x18: LD initialization in progress 0x19: LBA is out of range 0x1a: Maximum LDs are already configured 0x1b: LD is not OPTIMAL 0x1c: LD Rebuild is in progress 0x1d: LD is undergoing reconstruction 0x1e: LD RAID level is wrong for requested operation 0x1f: Too many spares assigned 0x20: Scratch memory not available - try command again later 0x21: Error writing MFC data to SEEPROM 0x22: Required HW is missing (i.e. Alarm or BBU) 0x23: Item not found 0x24: LD drives are not within an enclosure 0x25: PD CLEAR operation is in progress 0x26: Unable to use SATA(SAS) drive to replace SAS(SATA) 0x27: Patrol Read is disabled 0x28: Given row index is invalid 0x2d: SCSI command done, but non-GOOD status was received - see mf.hdr.extStatus for SCSI_STATUS 0x2e: IO request for MFI_CMD_OP_PD_SCSI failed - see extStatus for DM error 0x2f: Matches SCSI RESERVATION_CONFLICT 0x30: One or more of the flush operations failed 0x31: FW real-time currently not set 0x32: Command issues while FW in wrong state (i.e. GET RECON when op not active) 0x33: LD is not OFFLINE - IO not possible 0x34: Peer controller rejected request (possibly due to resource conflict) 0x35: Unable to inform peer of communication changes (retry might be appropriate) 0x36: LD reservation already in progress 0x37: I2C errors were detected 0x38: PCI errors occurred during XOR/DMA operation 0x39: Diagnostics failed - see event log for details 0x3a: Unable to process command as boot messages are pending 0x3b: Returned in case if foreign configurations are imcomplete 0x3d: Returned in case if a command is tried on unsupported hardware 0x3e: CC scheduling is disabled 0x3f: PD CopyBack operation is in progress 0x40: Selected more than one PD per array 0x41: Microcode update operation failed 0x42: Unable to process command as drive security feature is not enabled 0x43: Controller already has a lock key 0x44: Lock key cannot be backed-up 0x45: Lock key backup cannot be verified 0x46: Lock key from backup failed verification 0x47: Rekey operation not allowed, unless controller already has a lock key 0x48: Lock key is not valid, cannot authenticate 0x49: Lock key from escrow cannot be used 0x4a: Lock key backup (pass-phrase) is required 0x4b: Secure LD exist 0x4c: LD secure operation is not allowed 0x4d: Reprovisioning is not allowed 0x4e: Drive security type (FDE or non-FDE) is not appropriate for requested operation 0x4f: LD encryption type is not supported 0x50: Cannot mix FDE and non-FDE drives in same array 0x51: Cannot mix secure and unsecured LD in same array 0x52: Secret key not allowed 0x53: Physical device errors were detected 0x54: Controller has LD cache pinned 0x55: Requested operation is already in progress 0x56: Another power state set operation is in progress 0x57: Power state of device is not correct 0x58: No PD is available for patrol read 0x59: Controller resert is required 0x5a: No EKM boot agent detected 0x5b: No space on the snapshot repositiry VD 0x5c: For consistency SET PiTs, some PiT creations might fail and some succeed 0xFF: Invalid status - used for polling command completion
Com posse da mensagem de erro é possível iniciar um diagnóstico e iniciar um troubleshooting.